ASTM D5581
Related Standards: ASTM C670, ASTM D1559, ASTM E11
Resistance to Plastic Flow of Bituminous Mixtures Using Marshall Apparatus (6 inch-Diameter Specimen)
Qty. | Model | Description |
9 | Choose One: |
H-1367
|
Marshall Compaction Mold, 6" |
H-1367MM
|
Marshall Compaction Mold, 150mm |
1 |
H-1363
|
Marshall Mold Extractors, 6" |
1 | Choose One: |
H-1394
|
Water Bath, Large, Deluxe, 120V 60Hz |
H-1394.4F
|
Water Bath, Large, Deluxe, 220V 50/60Hz |
1 |
H-1353A
|
Asphalt Sample Ejector, Hand-Operated |
1 | Choose One: |
H-1366
|
Marshall Auto Compactor, Stationary Mold Configuration, 6" Dia. Specimens, 115V 60Hz |
H-1366.5F
|
Marshall Auto Compactor, Stationary Mold Configuration, 6" Dia. Specimens, 220V 50Hz |
H-1366.2F
|
Marshall Auto Compactor, Stationary Mold Configuration, 6" Dia. Specimens, 220V 60Hz |
1 |
H-1362
|
Marshall Breaking Head, 6" |
1 |
HM-5120A.3F
|
Load Frame, Marshall and TSR |
1 | Choose One: |
H-3841
|
Laboratory Bench Mixer, 5-Qt. (4.73L), 120V 60Hz |
H-3841.2F
|
Laboratory Bench Mixer, 5-Qt. (4.73L), 230V 60Hz |
H-3841.5F
|
Laboratory Bench Mixer, 5-Qt. (4.73L), 230V 50Hz |
1 | Choose One: |
H-7534
|
Guardian 7000 10"x10" Ceramic, Hotplate/Stirrer, 120V 50/60Hz. |
H-7534.4F
|
Guardian 7000 10"x10" Ceramic, Hotplate/Stirrer, 230V 50/60Hz. |
Note: Also required but not part of basic sets—Weighing balance, thermometers, various containers and labware.
Required but not Included in Basic Set
Qty. | Model | Description |
1 | Choose One: |
HT-4353
|
Thermometer, Longer-Stem, Digital: Accuracy of ±2.0°F / ±1.0°C. |
HT-4149U
|
Thermometer, Long-Stem, Multi-Angle Digital, Accuracy of ±0.4°C. |
1 | Choose One: |
HB-4787.3F
|
Adam Luna Precision Balance, 4600g x 0.01g, External Calibration – 120/220V 50/60Hz |
HB-4787C.3F
|
Adam Luna Precision Balance, 4600g x 0.01g, Internal/External Calibration – 120/220V 50/60Hz |
HB-4788.3F
|
Adam Luna Precision Balance, 6000g x 0.01g, External Calibration – 120/220V 50/60Hz |
HB-4788C.3F
|
Adam Luna Precision Balance, 6000g x 0.01g, Internal/External Calibration– 120/220V 50/60Hz |
HB-4789.3F
|
Adam Luna Precision Balance, 6000g x 0.1g, External Calibration – 120/220V 50/60Hz |
HB-4790.3F
|
Adam Luna Precision Balance, 8000g x 0.1g, External Calibration – 120/220V 50/60Hz |
HB-4506A
|
Ohaus Explorer High-Capacity Precision Balance, 12kg x 0.1g – 120V 60Hz |
HB-4506A.4F
|
Ohaus Explorer High-Capacity Precision Balance, 12kg x 0.1g – 220V 50/60Hz |
HB-4508A
|
Ohaus Explorer High-Capacity Precision Balance, 24kg x 0.1g – 120V 60Hz |
HB-4508A.4F
|